The industrial power plant KW Wählitz has a natural circulation boiler (150 tons / hour) and circulating, atmospheric fluidized bed firing. Our team supports the project with an IB-Advisor for the commissioning of the silo and the associated ancillary facilities.
Technical details:
Thermal input 119 MW
Electrical power 37.4 MW
Live steam parameter pressure: 115 bar,
Temperature: 535 ° C
Efficiency of the total plant 38.5 percent
Efficiency steam generator 91 percent