Project KW Wählitz

The industrial power plant KW Wählitz has a natural circulation boiler (150 tons / hour) and circulating, atmospheric fluidized bed firing. Our team supports the project with an IB-Advisor for the commissioning of the silo and the associated ancillary facilities.

Technical details:

Thermal input 119 MW

Electrical power 37.4 MW

Live steam parameter pressure: 115 bar,

Temperature: 535 ° C

Efficiency of the total plant 38.5 percent

Efficiency steam generator 91 percent